RETRODREAMSAMIGA & SPECTRUM
Menu

Fault guides · ZX Spectrum 48K Issue 2

ZX Spectrum 48K Issue 2No picture, won't boot

Step-by-step diagnosis for the ZX Spectrum 48K Issue 2 board. Each step lights up the signal or chip to measure in the explorer below.

You power it on and the Sinclair message never appears. Start with the voltages: on a Spectrum, a missing rail can kill the memory chips.

  1. The 5 V rail

    Measure at the output of the 7805 regulator: between 4.75 and 5.25 V. The regulator runs very hot in a Spectrum, which is normal; if the 5 V is low, switch off and look for a short.

    +5VShow on board →
  2. The +12 V rail

    The DC-DC converter (the two transistors and the coil next to them) makes the +12 V and −5 V the 4116 memory chips need. Measure the +12 V here.

    +12VShow on board →
  3. The −5 V rail

    If −5 V is missing while +12 V is present, the 4116s die. Always check it, and before powering a machine with new memory chips.

    -5VShow on board →
  4. Reset

    At power-on, the Z80’s _RESET rises after a moment, while a capacitor charges. If it stays stuck low, the Z80 never starts.

    _RESETShow on board →
  5. The clock

    The ULA derives the Z80’s 3.5 MHz clock from the 14 MHz crystal. Without a clock nothing runs: check the crystal and the ULA.

    _CLKShow on board →
  6. The Z80 at work

    _M1 pulses every time the Z80 fetches an instruction. If it pulses, the processor is alive; if not, go back to reset and the clock.

    _M1Show on board →
  7. The ROM

    The ROM holds BASIC and the start-up code. If the Z80 is working but the Sinclair message never appears, suspect the ROM.

    IC5 · ROMShow on board →

Didn't fix it?

We repair these boards on our bench in Loures. The request already includes the board and the fault.

Request a repair →

Drag to move; mouse wheel or two fingers to zoom. Tap a pad to follow the signal.